Every number in the config files carries a source tag. This file expands the tags and lists every external image, clip or dataset used, with its licence. Nothing is shipped without an entry here.
Guidelines and primary sources
| Tag | Reference |
|---|---|
| BTS23 | Roberts ME, Rahman NM, Maskell NA, et al. British Thoracic Society Guideline for pleural disease. Thorax 2023;78:1143-1156 (full guideline Thorax 2023;78 Suppl 3:s1-s42). https://thorax.bmj.com/content/78/11/1143 |
| BTS23 | Asciak R, Bedawi EO, Bhatnagar R, et al. British Thoracic Society Clinical Statement on pleural procedures. Thorax 2023;78(Suppl 3):s43-s68. doi:10.1136/thorax-2022-219371. https://pubmed.ncbi.nlm.nih.gov/37433579/ |
| SHM | Dancel R, Schnobrich D, Puri N, et al. Recommendations on the use of ultrasound guidance for adult thoracentesis: a position statement of the Society of Hospital Medicine. J Hosp Med 2018;13(2):126-135. https://cdn.mdedge.com/files/s3fs-public/Document/January-2018/jhm013020126.pdf |
| LIGHT | Light RW, Macgregor MI, Luchsinger PC, Ball WC. Pleural effusions: the diagnostic separation of transudates and exudates. Ann Intern Med 1972;77(4):507-513. |
| GRAY | Standring S (ed). Gray's Anatomy, 42nd ed. Elsevier 2020. Thorax and abdomen chapters. |
| SURF | Lumley JSP. Surface Anatomy, 5th ed. Elsevier; Moore KL, Dalley AF, Agur AMR. Clinically Oriented Anatomy, 8th ed. Wolters Kluwer. |
| HELM | Helm EJ, Rahman NM, Talakoub O, Fox DL, Gleeson FV. Course and variation of the intercostal artery by CT scan. Chest 2013;143(3):634-639. (Paravertebral exposure of the artery; tortuosity with age.) |
| SALAMONSEN | Salamonsen M, Ellis S, Paul E, Steinke K, Fielding D. Thoracic ultrasound demonstrates variable location of the intercostal artery. Respiration 2012;83(4):323-329. |
| BNF | Joint Formulary Committee. British National Formulary (online). BMJ Group and Pharmaceutical Press. Lidocaine hydrochloride: maximum dose without adrenaline 3 mg/kg (200 mg); toxicity (perioral numbness, tinnitus, drowsiness, then bradycardia and arrhythmia). https://bnf.nice.org.uk/drugs/lidocaine-hydrochloride/ |
| PROMPT | Values specified in the project brief for this simulator. |
Notes
- The config cites BTS23 for: minimum 10 mm fluid depth before aspiration, drainage limit 1.5 L without manometry, stopping for chest pain / cough / dyspnoea, no vacuum bottles or wall suction, ultrasound-guided site marking without moving the patient, and the posterolateral entry site lateral to the paravertebral region.
- The config cites SHM for the volume estimates (chest-wall-to-V-point > 9.9 cm, fluid across > 3 interspaces, each suggesting > 1 L).
- M4 (
thoracentesis.rules.ts,VITALS,RISK,COMPLICATIONS): every mentor rule carries one tag. BTS23 is cited only for statements in the guideline or the clinical statement (checklist and consent, side confirmation, coagulation correction where possible, ultrasound guidance and marking in the procedure position, aseptic technique, local anaesthetic to skin, periosteum and pleura, entry over the upper border of the rib lateral to the paravertebral region, the 1.5 L limit, stopping for symptoms, no suction, chest X-ray when air is aspirated or symptoms develop). BNF is cited for the lidocaine maximum and its toxicity profile. Everything else (risk base chances and weights, vitals time constants, response windows, the 100 mL/min "fast drainage" figure, the 3 mm bundle proximity, the 1 cm past-flashback limit) is a project teaching choice tagged PROMPT; the config comment beside each number says what it stands in for.
Ultrasound image references (M2 appearance; M7 clips)
The procedural B-mode renderer is tuned against real footage so that the signs look right (bat sign, quad sign, sinusoid sign, spine sign, jellyfish sign, plankton sign, mirror artefact, lung point). Each reference below is logged with its licence before it is used. Clips are only shipped under CC-BY, CC-BY-SA, CC-BY-NC, CC-BY-NC-SA, CC0, public domain, written permission or self-recorded; NoDerivatives licences and standard-licence YouTube are excluded.
| Id | Source | Licence | Used for | Status |
|---|---|---|---|---|
| US-01 | Atkinson P, et al. The V-line: a sonographic aid for the confirmation of pleural fluid. Crit Ultrasound J 2012;4:19, Figure 3 (effusion with spine sign, curvilinear). https://pmc.ncbi.nlm.nih.gov/articles/PMC3480906/figure/F3/ | CC BY 2.0 ("distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0)") | effusion grey level (near-pure black) vs liver (homogeneous mid-grey fine speckle); diaphragm only modestly brighter than liver; vertebral line as the brightest, blocky, discontinuous echo with shadow beneath | verified 2026-10-26 |
| US-02 | Gillman LM, Kirkpatrick AW. Portable bedside ultrasound: the visual stethoscope of the 21st century. Scand J Trauma Resusc Emerg Med 2012;20:18, Additional file 1 ("R apex batwing sign", linear, 2.6 cm). https://commons.wikimedia.org/wiki/File:Portable-bedside-ultrasound-the-visual-stethoscope-of-the-21st-century-1757-7241-20-18-S1.ogv | CC BY 2.0 Generic (file page) | bat sign on the linear probe: pleural line thickness and brightness vs muscle and fat, rib surface with full clean shadow, hazy low-grey lung speckle with faint A-lines | verified 2026-10-26 |
| US-03 | Ackermann F. LungandEffusion.ogv (lung moving within an effusion, curvilinear, 18 cm). https://commons.wikimedia.org/wiki/File:LungandEffusion.ogv | CC BY-SA 3.0 / GFDL (licence template on the file page) | jellyfish sign: atelectatic lung as tissue-grey flap with a bright surface line, near-field chest wall as a uniform grey band | verified 2026-10-26 |
| US-04 | Lichtenstein DA. Lung ultrasound in the critically ill. Ann Intensive Care 2014;4:1, Figure 2 (bat sign, A-line, seashore sign) and Figure 6 (stratosphere sign). https://pmc.ncbi.nlm.nih.gov/articles/PMC3895677/figure/F2/ and /figure/F6/ | Article CC BY 2.0; the figure captions say "Extract from 'Whole body ultrasonography in the critically ill' (2010 Ed) ... with kind permission of Springer Science", so the figures themselves may not be under CC BY | A-line spacing (repeat at the skin-to-pleura distance, dimmer and thinner than the pleural line); M-mode seashore (stratified lines above, fine sand below, finer than B-mode speckle) vs stratosphere (horizontal lines at every depth) | licence not confirmed for the figures, not shipped |
| US-05 | Schomynv. Barcode-Zeichen.jpg (M-mode in pneumothorax). https://commons.wikimedia.org/wiki/File:Barcode-Zeichen.jpg | Public domain ("released into the public domain by its author") | barcode sign: full-height horizontal bands of varying brightness, no granular zone | verified 2026-10-26 |
| US-06 | Hellerhoff. Leberhaemangiom mit Spiegelartefakt 56M - US - 001.jpg (liver mirror artefact across the diaphragm, curvilinear, 16 cm). https://commons.wikimedia.org/wiki/File:Leberhaemangiom_mit_Spiegelartefakt_56M_-_US_-_001.jpg | CC BY-SA 4.0 (licence template on the file page) | mirror artefact: liver texture duplicated above the diaphragm at the same grey level; diaphragm as a very bright, thin, smooth curve; liver grain size | verified 2026-10-26 |
| US-07 | Atkinson P, et al. (as US-01), Figure 2 (normal right base: echo-bright diaphragm, aerated lung above, no V-line above the diaphragm). https://pmc.ncbi.nlm.nih.gov/articles/PMC3480906/figure/F2/ | CC BY 2.0 (article statement as US-01) | normal counterpart of US-01: absent spine sign above the diaphragm, aerated-lung grey above the liver | verified 2026-10-26 |
Sources checked and not used for a specific image: The POCUS Atlas (thepocusatlas.com/legal states "Our content is licensed under the Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)" but also that it does not verify contributor ownership or consent; no clip chosen yet, re-check per clip before M7); Radiopaedia (CC BY-NC-SA 3.0 per radiopaedia.org/licence, attribution must name the contributor and the rID; not used in M2). Nothing in this table is shipped in M2: the image is procedural and carries a "Simulated" tag. Licence status was read on each file or article page on the date shown.
Tuning notes (M2 renderer, ULTRASOUND.display in the config). Fluid is rendered with texture "none" and the S-curve (contrast 0.4) so an effusion stays near-pure black against a mid-grey liver, as in US-01 and US-03; the reference level (referenceLevel 0.6) and a light log compression (logCompressionK 3) were chosen so liver and muscle sit in the middle of the grey scale rather than near white, with the speckle spanning roughly a quarter to two thirds of full white. The pleural line is drawn crisp, without speckle, at pleuralLineThicknessMm (1.5 mm) with interfaceBoost 1.25 so it is the brightest soft-tissue line, clearly above the striated muscle (US-02); muscle uses fibrillar speckle stretched 4:1 laterally for that striated look. A-lines come from the sampler, and the renderer adds only the coarse speckle of the dirty shadow, so each repeat stays dimmer than the pleural line (US-04). Liver and the mirrored liver share the same fine speckle (mirror flag forces the fine texture) so the mirror image matches the real liver in grain and grey level (US-06). M-mode speckle is static in depth for non-sliding samples and renewed every column for sliding lung, which gives stratified lines above the pleura and sand below (seashore, US-04), and horizontal lines at every depth over pleural air (barcode / stratosphere, US-04, US-05). Bone gets no speckle and a clean shadow, which keeps the vertebral line the brightest blocky echo in the effusion view (US-01).
Tuning notes (M5 renderer, ULTRASOUND.display and ULTRASOUND.sampler). The M2 display chain above is replaced by a scanner-style one (src/ultrasound/formation.ts, shaders.ts): the sampler writes a display level whose echo amplitude is echoSpanDb x (level - 1) dB; the renderer forms a complex scatterer field hashed on tissue coordinates, blurs it with the probe's point-spread function (axial pulse, lateral beam widening with depth, from probes[kind]), detects the envelope, log-compresses before scan conversion (60 dB dynamic range, reject 0.06), and applies compounding, a light log-domain speckle reduction and persistence. Grey levels were set by measuring the reference images (mean grey in a uniform box, 0..1): liver 0.25 (sd 0.06) in US-06 and 0.25 (sd 0.07) in US-01; aerated lung under the pleural line 0.16 in US-02; muscle band 0.27 in US-02; near-field skin and fat band 0.43 in US-06; pleural line and diaphragm peaks (95th percentile) 0.90 and 0.96 in US-02 and US-06; effusion median 0 in US-01. With gainReferenceDb -12 and interfaceBoostDb 6 the simulation gives liver 0.29 (sd 0.06), lung 0.20, muscle 0.24 and a pleural line near 0.9 at the default gain. Speckle grain follows the point spread (US-06: fine, laterally elongated, no dark net), fascia and the pleura are coherent thin lines at the field's boundaries (US-02), the diaphragm is a thin bright curve over a hypoechoic muscle (US-06), the collapsed lobe is tissue grey with a bright surface line (US-03), fat lobules are hypoechoic with interrupted septa (US-02, US-06 near field), and A-lines start 18 dB below the pleural line (US-02, US-04). Second pass: local contrast (mean |pixel - 3x3 mean| at the reference's mm per pixel) measured 0.0118 on US-06 liver, 0.0151 on US-02 muscle and 0.0058 on US-02 lung; the simulation gives 0.0105, 0.0125 and 0.0070 (compounding 0.85, log-domain speckle reduction 0.45, partly coherent lung haze 0.55, fine muscle fibre texture). US-01 is a down-sampled, smoothed figure (0.0031 at 0.41 mm per pixel) and was used for grey levels only. The beam now has a transmit focus (6 cm curvilinear, 2.5 cm linear) and diverges beyond it (lambda x depth / aperture: 2.6 mm at 24 cm curvilinear, 0.8 mm at 8 cm linear), and receiver noise amplified by the TGC lowers the far-field signal-to-noise ratio (US-01, US-03 far field). Third pass: specular interfaces follow a cos^2.5 angle law with a -22 dB diffuse floor (rib cortex arcs fade at their ends), vary along their length by a 10 dB tissue-anchored roughness, and the pleural line carries lung-anchored glints with short faint comet tails (US-02); every tissue has a two-octave low-frequency heterogeneity (4-14 mm cells); clean shadows hold a residual -47 dB side-lobe fill and soften with depth (1.0 mm + 0.25 mm per cm); near-field backscatter was raised so the linear near field matches US-02 (fat band 0.26 vs 0.27, muscle 0.29 vs 0.28, lung 0.17 vs 0.16; local contrast fat 0.0129 vs 0.0170, muscle 0.0130 vs 0.0150, lung 0.0066 vs 0.0058; liver 0.0105 vs 0.0118 in US-06).
Design reference
The UI tokens in DESIGN.md are taken from the author's own Aortic Root Atlas (https://aorticroot.vercel.app).
Tutorial references (#/learn, src/tutorial/tutorial.config.ts)
The ultrasound tutorial cites these sources in its step texts (footnotes [1] to [7] on the page map to TUT-01 to TUT-06 and US-01 above). Nothing from them is shipped: the tutorial image is procedural. Each page was read on the date shown and the cited statement found in it.
| Tag | Source | Licence | Cited for | Status |
|---|---|---|---|---|
| TUT-01 | Wikipedia contributors. Medical ultrasound. Wikipedia. https://en.wikipedia.org/wiki/Medical_ultrasound | CC BY-SA 4.0 (page footer) | "Most machines convert two-way time to imaging depth using an assumed speed of sound of 1540 m/s"; imaging frequencies "generally in the range of 1 to 18 MHz"; superficial structures "imaged at higher frequencies (7-18 MHz)", deeper structures "at lower frequencies (1-6 MHz)"; a linear transducer "with a frequency of 10 to 15 megahertz" for venous access; absorption "approximately 0.5 dB/(cm depth MHz)"; "white for a strong echo, black for a weak echo, and varying shades of grey for everything in between"; "Sonographic devices have trouble penetrating bone" | verified 2026-10-27 |
| TUT-02 | Sibai AN, Loutfi E, Itani M, Baraka A. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery: facilitation of internal jugular vein cannulation. M.E.J. Anesth 2008;19(6):1305-1320 (American University of Beirut, n = 100). https://www.aub.edu.lb/fm/Anesthesiology/meja/Documents/Ultrasound%20Evaluation%20of%20the%20anatomical%20characteristics%20of%20the%20Internal%20Jugular%20Vein%20and%20Carotid%20Artery.pdf | not stated; cited only | right IJV A-P depth from the skin 15.0 mm (SD 3.6, range 7-25), IJV A-P diameter 14.1 mm (SD 4.0, range 6-26), carotid A-P diameter 7.4 mm (SD 1.4, range 5-11), all in 30 degrees Trendelenburg; IJV lateral to the carotid in 51 %. The config uses 15 mm as the vein's centre depth and 14 mm as the width of a resting vein (the paper's 14.1 mm is an A-P diameter in head-down tilt; see the config comment) | verified 2026-10-27 |
| TUT-03 | Lena A, Raffaele F, Lo Iacono G, Geraci G, Cajozzo M. Anatomical variations of the internal jugular vein: the role of ultrasonography. Euromediterranean Biomedical Journal 2014;9(12):112-117. doi:10.3269/1970-5492.2014.9.12 (n = 830). https://iris.unipa.it/handle/10447/436749 | "protetti da copyright e tutti i diritti sono riservati" (repository page); cited only | mean IJV diameter 9.1-10.5 mm (by sex and side) and mean depth from the skin 9.8-12.5 mm; used for the resting vein A-P axis (9 mm) and as a check on the near-wall depth (10.5 mm) | verified 2026-10-27 (abstract page; the PDF is restricted) |
| TUT-04 | Czyzewska D, Krysiuk K, Dobrzycki K, Ustymowicz A. Ultrasound assessment of the jugular and vertebral veins in healthy individuals: selected physiological aspects and morphological parameters. J Ultrason 2015;15(62):267-273. doi:10.15557/JoU.2015.0023. https://pmc.ncbi.nlm.nih.gov/articles/PMC4657398/ | CC BY-NC-ND | IJV cross-sectional area significantly greater supine than sitting; sitting, the jugular veins were completely closed in 83.2 % (left) and 81.1 % (right) | verified 2026-10-27 |
| TUT-05 | Avgush K. DVT ultrasound compression technique: how much pressure is enough? Gulfcoast Ultrasound Institute blog, 1 September 2026. https://gcus.com/blog/DVT-Ultrasound-Compression-Technique-How-Much-Pressure-Is-Enough ; Salerno Rubeling A. POCUS DVT: don't miss a nonocclusive DVT. UMEM Educational Pearls, 29 July 2024. https://em.umaryland.edu/educational_pearls/4566 | not stated; cited only | GCUS: "apply steady pressure until you see the adjacent artery begin to compress slightly"; "If the artery begins to deform slightly and the vein completely collapses, that represents a normal compression response"; "the artery has a thicker wall than the adjacent vein"; the artery "remains visible and pulsatile". UMEM: "the vein should completely collapse with the same pressure to compress the neighboring artery" | verified 2026-10-27 |
| TUT-06 | RCEM Learning. Ultrasound: skills of ultrasound-guided vascular access. Basic science and anatomy: identification of structures. Royal College of Emergency Medicine. https://www.rcemlearning.co.uk/modules/ultrasound-skills-of-ultrasound-guided-vascular-access/lessons/basic-science-and-anatomy-2/topic/identification-of-structures/ | not stated; cited only | "Arteries tend to be circular in transverse view, with muscular walls, whereas veins are often oval"; "Veins are readily compressible, arteries are not" (added for the oval-versus-round statement, which TUT-01 to TUT-05 do not make) | verified 2026-10-27 |
Notes
- PROMPT values in
TUTORIAL(layer thicknesses, vessel positions, the 15 % arterial deformation, 8 % pulsation, 1 mm arterial wall, 6 mm probe sink, 20 degree vessel obliquity) are teaching choices from the project plan, not measurements; the config says so next to each. - Fluid looking near-black is cited to US-01 above (effusion grey level), shown as footnote [7] in the tutorial.
Signs course references (#/learn/signs, src/tutorial/signs/, src/i18n/en/signs.json)
The signs course (module 3) and the sign explanations (us.signWhy.*) cite these texts. Nothing from them is shipped: the image is procedural. The figures of LICH14 stay unshipped (see US-04). Each text was read on the date shown (Europe PMC full text) and the cited statement found in it.
| Tag | Source | Licence | Cited for | Status |
|---|---|---|---|---|
| LICH14 | Lichtenstein DA. Lung ultrasound in the critically ill. Ann Intensive Care 2014;4:1. doi:10.1186/2110-5820-4-1. https://pmc.ncbi.nlm.nih.gov/articles/PMC3895677/ | Article CC BY 2.0 ("open access article distributed under the terms of the Creative Commons Attribution License"); text cited, not reproduced; figures not shipped (US-04) | the pleural line is "half a centimeter below the rib line in adults" and with the ribs makes the bat sign, it "indicates the parietal pleura in all cases"; the A-line is the horizontal repetition of the pleural line and "indicates that air (gas more precisely) is the component visible below the pleural line"; lung sliding and the M-mode seashore sign "indicates that the lung moves at the chest wall" and that the pleural line also is the visceral pleura; the quad sign (pleural line, rib shadows, lung line) and the sinusoid sign ("The lung-line moves toward the pleural line on inspiration", "a low viscosity, allowing fine needle insertion"); the B-line "always arises from the pleural line, and always moves in concert with lung-sliding", is "long, well-defined, laser-like, hyperechoic, erasing A-lines", arises when "air and water are simultaneously hit by ultrasound beams, as occurring when subpleural interlobular septa are edematous", and "Three or more B-lines between two ribs are called lung-rockets"; the stratosphere sign of pneumothorax on M-mode; abolished lung sliding "is everything but specific" (ARDS, one-lung intubation, adherences, fibrosis, phrenic palsy, apnea); the lung point is "pathognomonic" | verified 2026-11-04 |
| ATK12 | Atkinson P, Milne J, Loubani O, Verheul G. The V-line: a sonographic aid for the confirmation of pleural fluid. Crit Ultrasound J 2012;4:19. doi:10.1186/2036-7902-4-19. https://pmc.ncbi.nlm.nih.gov/articles/PMC3480906/ (the same article as US-01 and US-07, here cited for its text) | CC BY 2.0 | above the diaphragm "the vertebral line ends abruptly as aerated lung does not permit transmission of sound waves", leaving a black "lung curtain"; "the presence of even a small amount of pleural fluid in the costophrenic angle acts as an acoustic window, allowing visualization of the vertebral bodies"; the V-line helps "differentiate anechoic fluid from the normal black lung curtain" | verified 2026-11-04 |
Notes
- TUT-01 (Wikipedia, Medical ultrasound) is also cited by the signs course, for: echoes at acoustic impedance changes, larger for a larger change, near-total reflection at gas or bone; A-lines as reverberations of the pleural line spaced at the skin-to-pleura distance, present over normal lung and over a pneumothorax; "A few B-lines that move along with the sliding pleura can be seen in normal lung", "three or more" abnormal; an effusion with "four distinct borders including the pleural line, two rib shadows, and a deep border". Read 2026-11-04.
- The mirror artefact is cited to US-06 (appearance) and to TUT-01 (near-total reflection at the lung surface); the geometry of the mirrored copy (echoes returning late are drawn deeper) is standard pulse-echo physics stated in TUT-01 (depth from echo time).
- The signs course's numbers (probe frequencies and resolutions, lung sliding travel, M-mode thresholds, the 10 mm pocket) come from
ULTRASOUNDandTHRESHOLDSinthoracentesis.config.tsandSIGNS_COURSEinsrc/tutorial/signs/signs.config.ts, throughvars. The B-line rates at the base and above an effusion (ULTRASOUND.bLines.basePerCm,effusionPerCm) and the M-mode sign thresholds (ULTRASOUND.mMode.signs) are PROMPT teaching values.